True


The Soft Tissue Seal of Patent™ Implants

Maximized soft-tissue adaptation to prevent periimplantitis

Clarico-Image-Text
Since dental implants are located partly inside the patient's body and partly in their oral cavity, the peri-implant soft tissue around them with its marginal epithelium represents a decisive defense barrier against attacks by bacterial pathogens from the outside world.
Healthy soft-tissue conditions around inserted Patent™ Implant after three months of healing (© Sebastian Horvath).
The stronger the soft-tissue adaptation to dental implants, the harder it is for pathogenic bacteria in the oral cavity to bypass the barrier of the marginal epithelium and to penetrate past the implant into the deeper tissue, where such bacteria would promote periimplant inflammation and marginal bone loss, among others. Moreover, once pathogenic bacteria have entered the body, they can gain access to the bloodstream, spreading to other parts of the body and contributing to the development of chronic disease. Recently, the World Health Organization recognized this as well and identified the oral cavity as the starting point of up to 70% of all chronic diseases.

Against this background, it would be all the more important with a view to the long-term health of implant patients if the soft tissues would connect to their inserted implants as tightly as possible. In the past, however, no synthetically produced material used in dentistry was able to achieve this. A sobering realization that also translates to the world of dental implants: There might be implant materials that favor soft-tissue adaptation more than others (for instance, zirconia offers more favorable soft-tissue reaction than titanium as this material causes far less inflammation of periimplant tissue). However, dental implants developed until now were – depending on the material used, more or less successfully – only able to achieve some degree of soft-tissue attachment, but not to bond with it in a complete and sustainable way.

Zircon Medical Management, manufacturer of the Patent™ Dental Implant System, is leading the way: Thanks to unique design factors and a fundamental understanding of the specific material properties of zirconia, the Swiss innovation company has succeeded not only in maximizing the soft-tissue integration of the Patent™ Implant, but in creating a veritable Soft Tissue Seal around its neck, largely sealing off the inside of the body from hostile attacks from the outside world. The benefit of this achievement, which is unparalleled in the world of dental implantology, is obvious: If the attachment of the soft tissue to a dental implant is so strong that bacterial pathogens in the oral cavity cannot penetrate past the implant into the deeper tissue, the risk of restoration-related complications in the body is minimized in the long term.

Groundbreaking combination of design and material

To create this strong Soft Tissue Seal, the Patent™ Implant harnesses a unique combination of design and material. Firstly, the Patent™ Implant has a tissue-level implant design. In clinical practice, this means that the implant is placed such that its crown margin is positioned at the level of the gingiva, preventing a bacteria-prone microgap at subgingival level. Thanks to the tissue-level implant design, cementation and preparation of the glass fiber post takes place at and above the gingival level, respectively, virtually eliminating the risk of tissue inflammation caused by subgingival cement. Secondly, in order to promote soft-tissue attachment during prosthetic restoration, the restorative procedure was designed in such a way that no insertion, replacement or removal of components is necessary. Thirdly, the Patent™ Implant features a 2.5 mm high collar that is machined and does not undergo any surface treatment after milling, in contrast to the highly rough portion that is placed in contact with the bone. The smoothness of the transgingival implant surface is a key prerequisite for the incredibly strong attachment of soft tissue in this area. Fourthly, the implant material plays a decisive role in the superior soft-tissue integration of the Patent™ Implant. Patent™ Implants are made of yttria-stabilized zirconia, a technologically advanced high-performance ceramic of the latest generation. Unlike titanium implants, zirconia ceramic implants stimulate an extremely low level of inflammation in the surrounding tissue, as a result of which the periimplant tissue begins to adhere to this material in a largely irritation-free way only a short time after the implant has been placed.
This was impressively demonstrated in an animal model study by Glauser and Schüpbach.[1] In histological analyses, the researchers observed that the soft-tissue seal around inserted Patent™ Implants remained constantly above gingival level after a healing period of four weeks and that this seal prevented the spread of calculus and plaque toward the underlying bone. In contrast, the researchers observed a significant accumulation around the titanium control implants of calculus and plaque, which spread downward toward the marginal epithelium, the point at which the body begins to react. 
Clarico-Text-Image
Histology of an inserted Patent™ Implant showing the tight Soft Tissue Seal after four weeks of healing (© Peter Schüpbach).
Furthermore, they found that the vertical histoarchitecture at the soft-tissue level around inserted Patent™ Implants—consisting of connective tissue, marginal epithelium and sulcular epithelium (biologic width)—has a highly favorable structure and is comparable in composition to that of the tissue around natural teeth. This is consistent with observations in the literature. Lee et al. describe, for example, that the proportion of connective tissue around ceramic implants (65.4%) is comparable to the proportion of connective tissue around natural teeth (65.8%).[2] In comparison, they observed a significantly lower proportion of connective tissue around titanium implants of only 38.1%.[2]

Scientifically proven long-term success 

The clinical benefits of the unique soft-tissue seal around inserted Patent™ implants are supported by scientific studies. For example, Brüll et al. and Becker et al. observed in their three- and two-year clinical studies that the proportion of keratinized gingiva around the Patent™ Implants examined increased over time.[3, 4] They also reported significantly lower probing depths of the gingival pockets around the Patent™ Implants and less bleeding on probing around the Patent™ Implants than around the natural teeth of the same patients. Long-term protection of the deeper tissue by the strong soft-tissue seal of the Patent™ Implant against the penetration of pathogenic bacteria has been proved by unique long-term studies. For example, Karapataki et al. followed over 90 inserted Patent™ Implants over a functional period of up to 12 years and found that, even after this long period of wear, none of the implants showed signs of periimplantitis.[5] In their long-term follow-up study, Becker et al. reported stable bone levels around inserted Patent™ Implants after a functional period of over nine years.[6]

Conclusion

The primary objective of every implant dentist should be to support the long-term health of their implant patients. With this in mind, Patent™ Implants with their soft-tissue seal represent a significant expansion of the treatment offering. The strong soft-tissue seal, which is unique among all implant systems on the market, on the one hand maintains long-term healthy soft-tissue conditions and on the other hand protects the bone beneath – not only in the short term, during the healing phase of the implant, but also demonstrably over the long term. With this unparalleled seal, the risk of complications associated with dental implant restorations is not merely reduced. It goes far beyond that: The Soft Tissue Seal around Patent™ Implants rather prevents biological complications, such as periimplantitis, periimplant mucositis or marginal bone loss, from occurring in the first place.
References:
1.    Glauser R, Schüpbach P. Early bone formation around immediately placed two-piece tissue-level zirconia implants with a modified surface: an experimental study in the miniature pig mandible. Poster presented at: Implant dentistry for all: honoring the past—treasuring the present—shaping the future. Academy of Osseointegration 2022 Annual Meeting; 2022 Feb 25; San Diego, CA.
2.    Lee DJ, Ryu JS, Shimono M, Lee KW, Lee JM, Jung HS. Differential healing patterns of mucosal seal on zirconia and titanium implant. Front Physiol. 2019 Jul 3;10:796. doi: 10.3389/fphys.2019.00796.
3.    Brüll F, van Winkelhoff AJ, Cune MS. Zirconia dental implants: a clinical, radiographic, and microbiologic evaluation up to 3 years. Int J Oral Maxillofac Implants. 2014 Jul-Aug;29(4):914-20. doi: 10.11607/jomi.3293.
4.    Becker J, John G, Becker K, Mainusch S, Diedrichs G, Schwarz F. Clinical performance of two-piece zirconia implants in the posterior mandible and maxilla: a prospective cohort study over 2 years. Clin Oral Implants Res. 2017 Jan;28(1):29–35. doi: 10.1111/clr.12610.
5.    Karapataki S, Fahrenholtz H, et al. Peri-implantitis and zirconia implants: results after five and up to 12 years of function. In preparation.
6.    Becker J, et al. Clinical performance of two-piece zirconium implants in the posterior mandible and maxilla: a prospective cohort study over nine years. In preparation.


The superior osseointegration of Patent™ Implants
An interview with Dr Roland Glauser, Switzerland

To install this Web App in your iPhone/iPad press and then Add to Home Screen.